Our Products
|
|
Digital Monitoring System for continuous non-invasive transcutaneous monitoring of Carbon Dioxide Partial Pressure ( pco2), Oxygen Saturation (Spo2), Pulse Rate (PR) Pulse Index ( PI) in various settings.
There has always been a need for a product for non-invasive continuous monitoring of PCO2, with Spo2 and PR for patient’s safety and better clinical outcome of patients in various settings like ICU, CCU, NICU, PICU, OT, Acute Surgical ward, Post Surgical ward, Recovery room, Respiratory ward, Sleep Diagnostics, Post operative Pain Management etc.
After lot of inputs and research a Swiss based company Sentec AG has come out with an outstanding product for continuous non- invasive transcutaneous monitoring for PCO2, Spo2, PR and PI of patients in the afore mentioned various settings. The measured signals are digitized , pre-analyzed, and controlled within the sensor head ie; right at the measurement site and the digital data is communicated to the monitor thus minimizes sensitivity to electromagnetic radiations and thus permits improved measurement performance, accuracy etc to deliver real time non-invasive monitoring of PCO2, Spo2,PR and PI.
|
SenTec Digital Monitoring System
|
- Non-invasive
- Continuous
- R eal-time
- PCO 2
- SpO2
- PR
The SenTec Digital Monitor (SDM) is a lightweight (2.5 kg) stand alone monitor with a TFT color display and an integrated, fully automatic calibration chamber. The SDM has a non-volatile FLASH memory which offers the possibility to record up to 12 days of patient data. The internal battery has a capacity of 6 hours.
|
|
|
Product Code - VS-A/P/N
The V-Sign™ Sensor is a digital sensor for noninvasive and continuous monitoring of transcutaneous carbon dioxide partial pressure (PcCO2), oxygen saturation (SpO2), and pulse rate (PR). It combines the elements of a Stow-Severinghaus type PCO2 sensor and a pulse oximetry sensor. The V-Sign™ Sensor uses SenTec’s patented digital sensor technology.
The V-Sign™ Sensor is suitable for pediatric and adult patients. In neonatal patients the use of the V-Sign™ Sensor is currently indicated for carbon dioxide tension monitoring only.
|
|
Reusable, sensor head consisting of single molded, sheath-like rubber tube, resilient to immersion Sensor cable: - Shielded silicone cable
- Length: 90 cm (length of SpO2 Adapter Cable: 150 cm, 250 cm, 750 cm (on request up to 920 cm))
Patients - Suitable for patients weighting more than 20 kg / 44 lbs
Measurement Principle - Transmissive 2-wavelength pulse oximetry
- Plug-in compatible with Nellcor™ non-OxiMax™ oximetry (Nellcor andOxiMax are registered trademarks of Covidien)
|
|
Product Code - AC-150 / AC-250 / AC-750 / AC-YYY A Sensor Extension Cable is required to connect the V-Sign™ Sensor to the SenTec Digital Monitor (SDM). Cables are available in three preconfigured lengths, customized cables (up to 920 cm) upon request. | Product Code | Product description | | AC-150 | Length = 150 cm | | AC-250 | Length = 250 cm | | AC-750 | Length = 750 cm | | AC-YYY | Customized length (up to 920 cm) |
|
|
|
Product Code - EC-A/P
Single-use Ear Clip for use with the V-Sign™ Sensor. The low-pressure Ear Clip with adhesive pad is used to attach the V-Sign™ Sensor to the ear-lobe of the patient.
The use of the Ear Clip is contraindicated for patients whose ear-lobes are too small to ensure adequate sensor application.
|
|
Disposables - Multi-Site Attachment Rings
|
Product Code - MAR-A/P/N
Single-use Attachment Ring for use with the V-Sign™ Sensor. MAR-A/P/N is intended to attach the V-Sign™ Sensor to various measurement sites for PCO2-only monitoring.
For neonates as well as for adults and pediatrics with sensitive (fragile) but intact skin.
|
|
|
Product Code - GEL-04
The Sensor Gel ensures an adequate contact between the patient’s skin and the V-Sign™ Sensor.
Each time the V-Sign Sensor is attached to the patient, one drop of Sensor Gel must be applied to the center of the sensor membrane or to the measurement site.
|
|
Disposables - Membrane Changer
|
Disposables - Membrane Changer Product Code - VS-DSET
The membrane and the electrolyte on the V-Sign™ Sensor must be changed periodically.
The change of the membrane and electrolyte is easy and straight-forward with the V Sign™ Disposable Set. This patented and innovative tool removes the old sensor membrane, cleans the sensor surface, and applies new electrolyte and a new sensor membrane in less than 1 minute by 4 simple press-and-turn movements.
|
|
Disposables - Service Gas
|
Product Code - GAS-0812
The Service Gas is used for calibration of the V-Sign™ Sensor in the Docking Station integrated into the SenTec Digtial Monitor.
Gas cylinder of 0.56 l, 9.5 bar (5.7 l at 1 bar, 21°C).
|
|
|
Product Code - V-STATS_CD
This PC based software is required for downloading SenTec trend data from the internal memory of the SenTec Digital Monitor to a PC. Data analysis includes detection and marking of events (e.g. desaturations, hypercapnia), artifacts and invalid measurement periods. The data analysis criteria are user adjustable. The results of the data analysis can be printed along with the graphs as a report.
Using V-STATS™ it is furthermore possible to configure different settings of the SDM.
Supported Languages:
English, German and French.
System Requirements:
Windows XP, Windows Vista SDMS SMB Software V06.10.xx or higher
|
|
|
Product Code - VS-TSET
The V-Sign™ Training Set is intended to exercise the exchange of the membrane of the V-Sign™ Sensor. The set contains a multiple-use Membrane Changer, a Dummy Sensor and 2 multiple-use Membrane Rings.
|
|
Clothing Clip for Sensor Cable
|
Product Code - SC-CC
The Clothing Clip secures Sensor Cables on the patient’s clothes or on the bed’s linen. Proper cable organization can help to reduce strain. To prevent dislocation of the sensor, no strain should pull on the sensor when attached to the patient.
|
|
|
Product Code - SDMS_CB
SDMS Carry Bag easily accommodates the SenTec Digital Monitor (SDM), the V-Sign™ Sensor (VS-A/P), a power cable as well as frequently used disposables. Documents (e.g. Quick Reference Quide, Instruction Manual) can be stowed in a specifically designed compartment. Its zipper top can be oped for monitoring during patient transport whereas its Velcro bottom can be opened to access the monitor's rear panel with the ON/OFF switch, the AC Power Connector, the sensor connection port and the different data communication ports.
|
|
|